CHEM-C2150 PROCESS DESIGN Exam: 8.4.2020

During the exam:

Read the questions very carefully!

Answer with pen and paper. Pay special attention to your handwriting and clarity of your answers! Answer in English, Finnish or Swedish.

Clearly mark the question numbers to your papers.

Use appropriate units in your calculations & answers.

Avoid logging out from MyCourses during the exam.

Avoid leaving the submission box during the exam.

Submitting your answers:

Write your name and student number on each page.

Take photo of each page with your smart phone.

Name your photos with student number and page number, for example 123456_1.xxx

THEORY PART: (30 points)

1. (10p) Explain the below Figure Net present value (NPV) vs Internal rate of return (IRR)

2. (10p) Draw the following process and correct any errors in the process controls

GA-1 FA-1

feed

to reactor FC TC

EA-1 steam

3. (5p) For which purposes the flash operation are used?

4. (5p) How to size storage tank and separation tank?

(2)

CALCULATION PART: (45 points)

5. (15p) Design a heat exchanger network grid for maximum heat recovery at Tmin = 10 °C.

By using the Pinch-analysis, it is known from the composite surves that the cold stream pinch temperature is 112 °C and the minimum hot and cold utilities are

Q 

H= 31.7 kW and

Q 

C= 180.4 kW. The streams are shown in Table 1.

Table 1: Streams data

Stream Heat-capacity flow rate,

m 

cp (kW/oC)

Supply

temperature (oC)

Target

temperature (oC)

H1 (hot) 3 122 33

H2 (hot) 1.9 175 52

C1 (cold) 2 40 135

C2 (cold) 1.8 70 160

6. (30p) In the following process, 2.5 t/h of fluid (density 800 kg/m3, cp=2.5 kJ/kg C) is pumped from S-1 (at atmospheric pressure) to S-2 (pressure 350 kPa). The stream is heated in EA-1 heat exchanger from 20 °C to 100 °C. The fluid is a light hydrocarbon mixture with a vapor pressure similar to water. The heating agent is at 3 bar steam (t=133.65 °C, h

= 2725.7 kJ/kg and l = 2164.2 kJ/kg). The entire length of the pipe is about 100 m and you can assume that 30 m of the pipe is before the pump. The heights of the equipment from the ground are shown in the Figure.

a. Size the pump GA-1 (head of the pump, NPSHA, hydraulic and shaft power) b. Size the heat exchanger EA-1 (duty, area, amount of steam needed)

c. Size all the pipes marked with solid line

GA-1 S-1

EA-1 steam

1,5m 5m

GA-2

DC-1 S-2

Viittaukset

LIITTYVÄT TIEDOSTOT

This value must be taken into account when the final design of the heat exchanger is calculated, but at the same time its effect on heat exchange and final

In order to solve glass temperatures during a tempering process, the problem is to find solving method for radiation heat flux, convection heat transfer coefficients and

KEYWORDS: Design for Additive Manufacturing, DfAM, Additive Manufacturing, Design for Six-Sigma, DFSS, Conjugate Heat transfer Analysis, Lattice Structures, Minimal Structures,

Poistokaasun sisääntulolämpötilan, ulostulolämpötilan ja veden lämpötilan avulla voidaan laskea poistokaasun keskimääräinen lämpötila sekä veden ja kaasun

In the first part, the reader is familiarized with the main information the research is related to – about ground source energy, needle heat exchanger, liquid coupled heat

Figure 7.15 The (a) total heat flow, (b) non-reversing heat flow, (c) reversing heat flow, and (d) quasi-static heat capacity curves of P(L/D)LA 96/4 obtained after three hours of

 Operating  voltage   influences  thermal  energy  storage  at  high  temperatures  more  drastically  than  lower  temperatures...   Heat   exchanger  area

The value interpreted from the amylograms are shown in Table 1. Hy- drothermal treatment at 90° C for more than 20 sec and at 100° C for all du- rations tested increased the